BKYRC - AKI-16 INDICATOR 14.7 OZ (ACID TEST KIT)
- MSDS: BKYRC
- Manufacturer: SPORLAN VALVE CO
- Product Name: AKI-16 INDICATOR 14.7 OZ (ACID TEST KIT)
- National Stock Number: 6665-01-020-3508
Product Identification
Product ID:AKI-16 INDICATOR 14.7 OZ (ACID TEST KIT)
MSDS Date:05/28/1991
FSC:6665
NIIN:01-020-3508
MSDS Number: BKYRC
Responsible Party
ST LOUIS, MO 63143
US
Emergency Phone: 314-647-2775
Info Phone: 314-647-2775
Preparer: JOHN E. HOFFMAN
Cage: 78462
Contractor
Telephone: 314-647-2775
Cage: 78462
Ingredients
XYLENE, DIMETHYLBENZENE, XYLOL
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 62%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM, SKIN
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ETHANOL (ETHYL ALCOHOL), TECSOL, ALCOHOL
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 36%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
TOLUENE
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 2%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PHENOL RED, PHENOLSULFONEPTHALEIN
CAS: 143-74-8
RTECS: SJ7490000
Fraction By Weight: TRACE
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: RESPIRATORY TRACT
IRRITATION, HEADACHE, DIZZINESS, & UNCONSCIOUSNESS. SKIN:
ABSORPTION.
Explanation of Carcinogenicity:NONE
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. INGESTION: DON'T INDUCE
VOMITING. EYES/SKIN: FLUSH W/WATER FOR 15 MINUTES. OBTAIN MEDICAL
ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:44F
Extinguishing Media:CO2, DRY CHEMICAL, FOAM
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUIDS. VAPORS OF THE SOLUTION
HAS A MODERATE EXPLOSION HAZARD WHEN EXPOSED TO HEAT OR FLAME.
Accidental Release
Spill Release Procedures:REMOVE IGNITION SOURCES. VENTILATE AREA. FLUSH
SMALL AMOUNTS W/WATER OR MOP UP. LARGE AMOUNTS MAY BE COLLECTED
W/ABSORBENT MATERIAL. AVOID INHALING VAPOR OR SKIN CONTACT.
Handling
Handling and Storage Precautions:DON'T STORE SOLUTIONS >120F. AVOID
INHALING VAPORS OR SKIN CONTACT.
Exposure Controls
Respiratory Protection:USE APPROVED RESPIRATOR
Ventilation:PROPERLY TO KEEP CONCENTRATION BELOW LOWEST TLV LIMIT
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GOGGLES
Supplemental Safety and Health
PRODUCT IS A ACID TEST KIT USED TO DETERMINE THE ACIDITY OF OIL FROM
AIR CONDITIONING & REFRIGERATION SYSTEMS.
Chemical Properties
Boiling Pt:B.P. Text:182F
Melt/Freeze Pt:M.P/F.P Text:-75F
Vapor Pres:40
Vapor Density: 2
Spec Gravity:0.833
pH:7
Solubility in Water:SLIGHT
Appearance and Odor:YELLOW-ORANGE-RED
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS
Stability Condition to Avoid:HEAT, FLAME
Disposal
Waste Disposal Methods:COLLECT FOR INCINERATION IN ACCORDANCE
W/FEDERAL, STATE, & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.